What voltage is a shaver socket?
What voltage is a shaver socket?
A shaver socket-outlet conforming to BS 4573 has a restricted continuous current rating of 200 mA for use on voltages of 200 V to 250 V a.c. only. The shaver socket-outlet incorporates a current limiting device, other than a fuse, which may be of either the manually-resetting or the self-resetting type.
What voltage is a UK shaver socket?
240V
The UK uses 240V electrics whereas the USA uses 110V. Most electric toothbrushes bought in the UK and Europe have charging stands that work on 220-240V.
Why are UK shaver sockets dual voltage?
Why do the two-pronged Shaver Sockets in the UK have two sets of connectors? In the UK, you can often find two-pronged sockets in bathrooms; the idea of these is that they offer a lower voltage than standard three-pronged sockets, so are safer to use for charging lower-powered devices.
What zone can a shaver socket go in?
zone 2
Can you install electric shaver sockets in a bathroom? According to the updated 17th edition of the IEE Wiring Regulations, it is safe to install electric shaver sockets in your bathroom providing the socket is 110v and installed in zone 2 or beyond, with at least a 3-metre gap from either the bath or shower.
Can you spur off a shaver socket?
A shaver socket must only supply one item. If there are two outlets they both must have their own isolated windings. They are type tested and it is not permissible to alter them and although it would seem safer to have the transformer remote from socket it is not allowed.
How do dual voltage shaver sockets work?
Shaver sockets contain a transformer which isolates the mains supply from earth. The voltage is the same, or 115V for the centre-tapped output. If you were to touch one of the two output pins, then you would not get a shock – you’re connected to ground, but the output side of the transformer isn’t.
Can a shaver socket be in Zone 1?
Shaver sockets are becoming a common feature in bathrooms, whether they are directly installed into the wall, or they come as a feature in a mirrored cabinet. In relation to bathroom zones, shaver socket regulations state that one must be placed at least 3m horizontally from the boundary of zone 1.
Can you fit a shaver socket in Zone 2?
According to the updated 17th edition of the IEE Wiring Regulations, it is safe to install electric shaver sockets in your bathroom providing the socket is 110v and installed in zone 2 or beyond, with at least a 3-metre gap from either the bath or shower.
Can you plug bathroom mirror into shaver socket?
Yes, in principal supplying from a fused connection unit would be fine however, you need to be mindful where you site the connection unit. Thanks for the reply. It will be positioned above the bathroom sink.
Can you sell electrical items with European plug?
Distributors and retailers, including second-hand dealers and auctions, must only sell appliances that are correctly fitted with an approved plug, with sleeved neutral and live pins, and the correct fuse. Electric fires for use in the home must have a fireguard that meets British standards, or the European equivalent.